Neonatal Acls Emergency Training System (Wireless) Edcation Teaching Model

Product Details
Customization: Available
Condition: New
Customized: Customized
Gold Member Since 2017

Suppliers with verified business licenses

Audited Supplier

Audited by an independent third-party inspection agency

Importers and Exporters
The supplier has import and export rights
High Repeat Buyers Choice
More than 50% of buyers repeatedly choose the supplier
In-stock Capacity
The supplier has In-stock capacity
Quality Assurance
The supplier provides quality assurance
to see all verified strength labels (16)
  • Neonatal Acls Emergency Training System (Wireless) Edcation Teaching Model
  • Neonatal Acls Emergency Training System (Wireless) Edcation Teaching Model
  • Neonatal Acls Emergency Training System (Wireless) Edcation Teaching Model
  • Neonatal Acls Emergency Training System (Wireless) Edcation Teaching Model
  • Neonatal Acls Emergency Training System (Wireless) Edcation Teaching Model
  • Neonatal Acls Emergency Training System (Wireless) Edcation Teaching Model
Find Similar Products
  • Overview
  • Product Parameters
  • Detailed Photos
Overview

Basic Info.

Model NO.
XY-ACLS-400
Material
PVC
Type
Medical Education Training Model
Delivery
10days
Shipment
by Sea,Air,Express
Purpose
Hospital School etc
Position
Full Body Simulator
Transport Package
Paper Ctns
Specification
50cm*25cm*30cm 20KGS
Trademark
XINYI
Origin
Shanghai, China
HS Code
90230090
Production Capacity
200PCS/Month

Product Description

 
Product Parameters

XY-ACLS-400 Neonatal Acls Emergency Training System (Wireless)

Features:
 
This sign indicates that the functions can be run only when the manikin is used with the optional accessories Head and neck: 

1. Normal, dilated pupil;
2. Airway management: realistic mouth, nose, tongue, gum, throat, esophagus, epiglottis, trachea, tracheal ring ; can practice tracheal intubation via mouth or nose, sputum suction; oxygen inhaling; may monitor airway intubation and umbilical vein catheterization, show correct and wrong intubation; there is prompt for wrong tracheal intubation; only right chest rise can be observed due to excessive intubation position;
3. Gastric intubation: detect tube position via auscultation; inserting gastric tube for gastrointestinal decompression, nasal feeding, gastric lavage, etc.
 
Chest and abdomen:
 
1. Pneumothorax puncture extraction, pleural effusion extraction training;
 2. Auscultation sound: include heart sound, breath sound, bowel sound, of which the normal heart sound and breath sound can be adjusted according to the monitor HR and respiratory rate;
 3. CPR training: Support multiple ventilation ways: mouth to mouth, mouth to nose, BVM to mouth; can monitor inflation times and frequency, compression time, frequency and depth; judge the ratio of artificial breathing and chest compression;
 
Real defibrillation and pacing: Achieve real defibrillation and pacing by using with real defibrillating pacer(prepared by user-self); 
ECG monitoring: Be used with real ECG monitor (prepared by user-self) to realize ECG monitoring; 
Simulative ECG monitoring should be used with multi-parameter simulation of ECG to achieve the function of monitoring ECG. 
Simulate defibrillation and pacing: should be used with simulative defibrillating pacer; can choose defibrillation energy, the max energy is 360J; 

Limbs:
 
1.Venous transfusion/puncture, arm veins include and Scalp vein includes. 
2.Umbilical care: Practice ligature of umbilical cord, umbilical vein catheterization; 
3.Bone marrow puncture: Effusion of simulative bone marrow prompts proper tibial puncture; can inject into drugs and practice transfusion; 
4.BP measurement training 

Software:
 
1.Vital signs monitoring: spontaneous breath; simulate femoral artery, umbilical artery pulse; heart rate, cardiac rhythm, crying, hiccupping, BP, saturation of blood oxygen, ABP, mixed cyanosis, central cyanosis, peripheral cyanosis, amniotic fluid, muscular tension, convulsion, reflection, spontaneous movement and general paralysis; can perform Apgar score; 
2.ECG, emergency scenes and cases are available in the system; 
3.Neonatal ACLS emergency script editor is used to edit neonatal emergency cases and simulate emergency scenes;
4.Neonatal ACLS emergency script training software 
5.Perform PETCO2: confirm tracheal intubation position and monitor the effectiveness of resuscitation operation

Standard components: 
1.Intelligent ACLS Neonate Manikin 
2.BP Training Equipment 
3.Heart and Lung Auscultation Simulator Set 
4.ECG Generator 
5.Defibrillator Converter 
6.BVM, Stethoscope, Laryngoscope, Tracheotomy tube, Infusion set. 
7.Emergency System Controller 
8.Medical Air Compressor 

Optional accessories:
 1.Video monitoring equipment 
2.Computer 
3.Computer control console 
4.Stainless steel control console 
5.Rescue operation statio
Detailed Photos
Neonatal Acls Emergency Training System (Wireless) Edcation Teaching Model
Neonatal Acls Emergency Training System (Wireless) Edcation Teaching Model
Neonatal Acls Emergency Training System (Wireless) Edcation Teaching Model
Neonatal Acls Emergency Training System (Wireless) Edcation Teaching Model
Neonatal Acls Emergency Training System (Wireless) Edcation Teaching Model

 

Send your message to this supplier

*From:
*To:
*Message:

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now
Contact Supplier